Product Details:
| Material | Stainless Steel |
| Display | Digital |
| Application Media | Any Liquid |
| Brand | Endress Hauser |
| Usage/Application | industrial |
| Temperature | 0-250 C |
| Repeatability | 1% |
| Flow Range | 0-25 m3/hr |
| Model Name/Number | Prowirl F 200 |
| Power Supply | 24 DC |
| Color | Blue |
| Accuracy | 1% |
| Frequency | 50 HZ |
| Communication | RS 485 |
| Pressure Rating | 0-10 bar |
| Protect class | IP 68 |
| Nominal Pressure | 0-1 bar |
| Operating Pressure | 0-10 bar |
| Max Pressure | 0-16 bar |
Volume flow (liquid): ±0.75 %
Volume flow (optional): ±0.65 %
Volume flow (steam, gas): ±1.00 %
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): ±0.85%
Product Details:
| Display | Digital |
| Brand | ABB |
| Application Media | STEAM / GAS / LIQUID |
| Material | Stainless Steel |
| Temperature | Upto 300 |
| Communication | 4-20 mA |
Introduction
Vortex Flowmeter is based on Carmen Vortex Principle, which adopts piezoelectric crystal as testing
components. It is a new kind of stress detecting vortex flowmeter. It has the advantages of wide range rate,
high accuracy, low pressure loss, good medium generality, pulse signal output proportional to flow, conveni
ent to connect with computer etc.
Vortex Flow Meters are suitable for a variety of applications in liquid, gas, air, and steam flows. These volumetric flow measuring devices are constructed with stainless steel bodies which provide accurate and reliable measurement for years in industrial service.
Where to Use Vortex Flow Meters
Gas: air,oxygen,carbon dioxide,nitrogen,natural gas,lpg,biogas,etc
Liquid: water,oil,etc
Steam:saturated steam and superheated steam,vapor etc
Additional Information:
Product Details:
| Display | Digital |
| Brand | Rosemount |
| Application Media | Any Liquid |
| Usage/Application | Industrial |
| Material | Stainless Steel |
| Temperature | 0-150 C |
| Model Name/Number | 8800D |
Flow Meter Accuracy
± 0.65% of volumetric rate for liquids
± 1% of volumetric rate for gas and steam
± 0.70% of mass flow rate in water using MultiVariable option
± 2% of mass flow in steam using MultiVariable optio
Turndown:
38:1
Output
4-20 mA with HART® 5 or 7
4-20 mA with HART® 5 or 7 and Scalable Pulse Output
FOUNDATION; fieldbus ITK6 with 2 Analog Input blocks, 1 Backup Link Active Scheduler function block, and 1 Integrator function block (1 PID function blo
Wetted Material
Stainless Steel – 316/316L and CF3M
Nickel Alloy – C-22 and CW2M
High Temp Carbon Steel – A105 and WCB
Low Temp Carbon Steel – LF2 and LCC
Duplex UNS S32760 and 6A
Consult factory for other wetted material
Flange Options
ANSI Class 150 to 1500
DIN PN 10 to PN 160
JIS 10K to 40K
Flanges are available in a variety of facings
Consult factory for additional flange ratings
Operating Temperatures
-330°F to 842°F (-200°C to 450°C)
Line Size
Flanged: ½-in to 12-in (15 to 300 mm)
Wafer: ½-in to 8-in (15 to 200 mm)
Dual: ½-in to 12-in (15 to 300 mm)
Reducer: 1-in to 14-in (25 to 350 mm)